Da-Lite TENSIONED EXECUTIVE ELECTROL Installation Manual

Browse online or download Installation Manual for Projection screens Da-Lite TENSIONED EXECUTIVE ELECTROL. Da-Lite Tensioned Executive Electrol User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
DA-LITE SCREEN COMPANY, INC.
3100 North Detroit Street
Post Office Box 137
Warsaw, Indiana 46581-0137
Phone: 574-267-8101
800-622-3737
Fax: 574-267-7804
www.da-lite.com
Instruction Book for
TENSIONED EXECUTIVE ELECTROL®
The Da-Lite Difference.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - The Da-Lite Difference

DA-LITE SCREEN COMPANY, INC.3100 North Detroit StreetPost Office Box 137Warsaw, Indiana 46581-0137Phone: 574-267-8101800-622-3737Fax: 574-267-7804www.

Page 2 - IMPORTANT SAFETY INSTRUCTIONS

PRE-INSTALLATION1INSTALLATION 1. Position screen under mounting location with the case opening down. 2. Install screen by raising unit into posit

Page 3 - INSTALLATION

The picture surface drop, and the opening and closing of the fabric door, are controlled automatically by limit switches which have been preset at Da-

Page 4 - FALSE TOP

1⁄4" x 2"LAG SCREWTENSIONED EXECUTIVE ELECTROL® INSTALLATION3SUGGESTED METHODS OF INSTALLATIONTYPE 1 & 2Offset mounting, recessed above

Page 5 - INSTALLATION

TENSIONED EXECUTIVE ELECTROL® INSTALLATION4BLACKRED (UP)BLUEBLACKWHITEWHITEREDUP LIMIT SWITCH(OPERATED BY DOOR)CAPACITORBLACK(DOWN)DOWN LIMIT SWITCHDO

Page 6 - TROUBLESHOOTING

TROUBLESHOOTINGSYMPTOM 1. Screen will not operate or will not go “down”. Motor does not hum. 2. Motor hums.CAUSE(a) Blown fuse.(b) Tripped

Page 7

6TROUBLESHOOTINGSYMPTOM 3. Screen will not move “up.” Motor does not hum. Motor hums.CAUSE(a) No power between red and white leads in junct

Page 8

TROUBLESHOOTING SYMPTOM 9. Screen jammed. Will not operate, motor hums, door open, closing mechanism detached from door.CAUSE(a) Closing mechanism